ATPV-NH3 (NT3) DC1000V PV Fuse Link

Industrial NH3 solar fuse, the ideal heavy-duty protection for main DC outputs in high-power PV combiner boxes and utility-scale solar arrays.

50kA Breaking Capacity: Superior fault interruption for system safety.
Combiner Box Optimized: Perfect fit for NH3-size central distribution.
High-Current Support: Reliable 125A-630A protection for DC busbars.
Standard Compliant: Certified to IEC 60269-6 for outdoor PV use.

Available Current (A):

125A
160A
200A
250A
315A
355A
400A
450A
500A
550A
600A
630A
Follow for Updates
🛡️

High Safety

50kA breaking capacity @ 1000V DC ensures ultimate circuit protection.

⚡

Low Power Loss

Optimized fuse element design reduces heat generation and energy waste.

📜

Certified Quality

Fully compliant with IEC 60269-6 and global international solar standards.

Technical Specifications

Dimension Drawing (mm)

ATPV-NH1 Dimensions
Rated Voltage (Un)DC 1000V
Rated Current (In)125A, 160A. 200A, 250A, 315A, 355A, 400A, 450A, 500A, 550A, 600A. 630A
Breaking Capacity50kA
Utilization CategorygPV (Solar Photovoltaic Protection)
StandardIEC 60269-6, GB/T 13539.6

Fuse Cold Resistance and Power Dissipation

No.Rated Current (A)Pre-arcing I²tTotal I²t1In (W)
01125A31501770813.5
02160A42442385916.0
03200A55843139421.0
04250A73474130827.0
05350A115606499537.0
06400A137207709042.0
07 450A 15500 86800 48.0
08 500A 17200 96400 53.0
09 550A 18900 106000 58.0
10 600A 20600 116000 63.0
11 630A 21600 122000 66.0

Time-Current Characteristic

rated current (A)Standard: IEC60269-6Standard: UL248-19
105%135%135%200%
In≤30>1h non fusing<1h fusing<1h fusing12-240s
30≤In≤60>1h non fusing<1h fusing<1h fusing12-360s
60≤In≤100>2h non fusing<2h fusing<1h fusing0-480s
100≤In≤200>2h non fusing<2h fusing<1h fusing0-600s
200≤In≤400>3h non fusing<3h fusing<1h fusing0-720s
400≤In≤630>4h non fusing<4h fusing<1h fusing0-720s

Melting characteristic curve

Time-Current Characteristics (50A-160A)

TIME (S)
ATPV-NH3 Time-Current Curve
CURRENT (A)

Time-Current Characteristics (125A-250A)

TIME (S)
ATPV-NH3 Cut-off Current Curve
CURRENT (A)

Time-Current Characteristics (250A-400A)

TIME (S)
ATPV-NH3 Cut-off Current Curve
CURRENT (A)

Time-Current Characteristics (350A-630A)

TIME (S)
ATPV-NH3 Cut-off Current Curve
CURRENT (A)

Need a complete solution?

For enhanced safety and easy maintenance, we recommend pairing the ATPV-NH3(NT3) fuse with our
ATPV-NH3D Fuse Base.

ATPV-NH3(NT3) DC Fuse Link Applications

check
Main DC Output of Combiner Boxes
check
BESS Battery Cluster Protection
check
Central Inverter DC Input
check
Utility-Scale Solar Power Plants
check
DC Distribution Cabinets
check
Power Conversion Systems (PCS)
check
EV Fast Charging Stations (Power Stack)
check
Industrial Microgrid Infrastructure

Frequently Asked Questions

1. What is a photovoltaic fuse, and why do photovoltaic systems need to use dedicated fuses?
▼
Photovoltaic fuses are specifically designed for DC PV systems, enabling them to quickly disconnect circuits under high DC voltage and low fault current conditions, protecting the safe operation of modules, inverters, and energy storage devices.
2. Can ordinary gG fuses be used to replace photovoltaic fuses in PV systems?
▼
Ordinary gG fuses are not recommended because they cannot effectively handle the special fault characteristics of DC arcs and photovoltaic systems.
3. How to select the rated current of a photovoltaic fuse?
▼
Typically, the rated current of a fuse is selected to be approximately 1.6–2.5 times the maximum operating current to ensure reliable protection. Of course, you can also tell us the operating current of your circuit, and we will help you select the appropriate type.
4. Are photovoltaic fuses reliable in outdoor environments?
▼
High-quality photovoltaic fuses can operate stably for extended periods under conditions of high temperature, high humidity, ultraviolet radiation, and significant diurnal temperature variations, making them suitable for outdoor photovoltaic applications.
5. What type of fuse should be used to protect a PV inverter, and where should it be installed?
▼
To effectively protect a photovoltaic (PV) inverter, the fuse should be installed on the DC input side to the inverter. The recommended fuse type is a gPV fuse, which is specifically designed for photovoltaic applications. The fuse must comply with IEC 60269-6, the international standard for low-voltage fuses used in PV systems.
6. Which countries do you have exclusive distributors in?
▼
Currently, we have exclusive distributors in India, Turkey, and Brazil. We are also happy to discuss exclusive distribution partnerships with partners from other countries.
7. What is the MOQ? If I only need samples or products for personal use, how can I buy them?
▼
Our MOQ is 100 PCS. If you only need samples or a small quantity for personal use, we can provide sample quantities. Please feel free to contact us for details.

Get a Professional Quote

Have questions about our PV Combiner Box? Fill out the form below and our technical team will contact you within 24 hours.